Power Supply China of 6-20KVA UPS Power with Output PF 0.9
Features
1.DSP control ,with excellent performance and comprehensive protections for load and UPS
2. Output power factor 0.9,offering more stronger load capability
3.Intelligent fan speed control ,with 4 levels varying according to load and temperature
4.Wide input range ,support kinds of generator
5.Dual input AC source supportable
6. EPO(emergency power off)
7.Event log up to 100 events, recording UPS running time and critical memories
8. High efficiency (ECO mode)option
9.Intelligent N+X parallel redundancy, up to 6units
10.AC and cold start function
11. Human friendly large LCD, with plenty operation information
12. Conformal coating PCB for more critical operation environment
13. 3:1phase into single phase easy convertible (10-20Kva)
14. Frequency Convertor mode:input 50Hz,output 60Hz or reverse
15. Most advanced 3 electrical level inverter designfor 15-20kva
16. Extremely low failure rate and easy repair(MTBF>80000h,MTBR<0.5h)
17.Intelligent 10A charger,prolong battery lifespan by above 20%:interval three-stage charging process( constant current.constant voltage, float charging) with inverse battery connection protection(option)
18. Multiple communication ports ,SNMP card, AS400 card(optional)
Technical Specification
Model | PCP06S | PCP06L | PCP10S | PCP10L | PCP3110 | PCP3115 | PCP3120 | ||||||||||||
Capacity(Kva/kW) | 6KVA/5.4kW | 10KVA/9kW | 15KVA/13.5KW | 20KVA/18kW | |||||||||||||||
Input | |||||||||||||||||||
Phase | 1/1PHASE, 1wire+N+G | 3/1APHASE, 3Wires+N+G | |||||||||||||||||
Input PF | ≥0.99 | ≥0.95 | |||||||||||||||||
Input voltage | Low transfer | L-N:176 VAC ± 3% @ 100% load;130 VAC ± 3% @ 50% load | |||||||||||||||||
Low back | L-N:188 VAC ± 3% @ 100% load,142 VAC ± 3% @ 50% load | ||||||||||||||||||
High transfer | L-N:286 VAC ± 3% | ||||||||||||||||||
High back | L-N:270 VAC ± 3% | ||||||||||||||||||
Input frequency | 40-70hz | ||||||||||||||||||
Battery | |||||||||||||||||||
Rating/type | 12V/7Ah | depend on external battery | 12V/9Ah | depend on external Battery | depend on external battery capacity | ||||||||||||||
quantity | 20 | 20 | |||||||||||||||||
Back up time | 6mins | depend on external battery | 4mins | depend on external Battery | |||||||||||||||
DC voltage | 240Vdc | ||||||||||||||||||
Charge voltage | 275Vdc | ||||||||||||||||||
Recharging current | 1A | 4A | 1A | 4A/10A(option) | |||||||||||||||
Output | |||||||||||||||||||
Output P.F | 0.9 | ||||||||||||||||||
Output voltage | 220/230/240Vac +/-1%(static) | ||||||||||||||||||
Frequency | 46~54Hz or 56~64Hz (Line mode) | ||||||||||||||||||
Crest factor | 3:1(max) | ||||||||||||||||||
Wave distortion | Less than 2%(linear load), Less than 4% Non-linear load | ||||||||||||||||||
Over load | 105%<load<125% for 1 mins ,125%<load<150% for30sec | ||||||||||||||||||
Efficiency | 92%(Line mode) | ||||||||||||||||||
98%(ECO mode) | |||||||||||||||||||
Transfer time | 0ms (AC-Battery); | ||||||||||||||||||
0 ms(bypass-inverter) | |||||||||||||||||||
Indicator | |||||||||||||||||||
LCD Panel | UPS status, Load level, Load watt,Load VA,Battery level, Input/Output voltage, output current,Bus voltage, Temp, and warning and fault code and events | ||||||||||||||||||
Alarm | |||||||||||||||||||
Battery Mode | Sounding every 4 seconds( can mute) | ||||||||||||||||||
Low Battery | Sounding every second | ||||||||||||||||||
Overload | Sounding every second | ||||||||||||||||||
Fault | Continuously sounding | ||||||||||||||||||
Management | |||||||||||||||||||
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC | ||||||||||||||||||
Optional | SNMP/AS400/USB | ||||||||||||||||||
Environment | |||||||||||||||||||
Operation Humidity | 0-90 % RH (non-condensing) @ 0- 40°C | ||||||||||||||||||
Noise Level | Less than 55dBA @ 1 Meter | Less than 58dBA @ 1 Meter | |||||||||||||||||
Physical | |||||||||||||||||||
Net Weight (KG) | 62 | 22 | 76 | 29 | 36 | 45 | 45 | ||||||||||||
Gross Weight(KG) | 74 | 35 | 88 | 41 | 48 | 58 | 58 | ||||||||||||
Unit Dimension (D*W*H)mm | 582*260*642 | 600*300*740 | |||||||||||||||||
Packing (D*W*H)mm | 680*360*810 | 720*420*920 |
Note:6-10kva 120Vac models are available ;
All specifications subject to change without further notice; customized specifications are acceptable
PACKING & SHIPPING
Packing:
1-20KVA ONLINE HF UPS: CARTON PACKING WITH PALLET
6-600KVA ONLINE LF UPS and 10-120KVA ONLINE HF UPS: WOODEN PACKING WITH PALLET
Shipping: 3-4 WEEKS AFTER PREPAYMENT ; BY SEA/EXPRESS/AIR
About us
warranty
1-20KVA UPS : 18 months from shipment date
3/3 phase UPS : 2 years from shipment date
If any part fails within warranty and needs repairing or replacing, please send part or board back to us (customer pay the freight fee), Or you provide the exact details information as per our requirement, and we offer you free spare parts and send to you(customer pay the freight fee)
our service
1. Professional technical and business service before and after selling.
2. Professional free engineer training course in our factory or abroad.
3. Customer market protection policy.
4. Short delivery time and good quality and good price
5. fast and effective online technical and business support.
Our Mission and Vision :
Mission: Produce high quality UPS product and power solution to worldwide partners for middle and high end market;
Vision : To be a world-class company in UPS industry.
FAQ
1 what is uninterrupted power supply
An uninterruptible power supply, also uninterruptible power source, UPS, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, super capacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.
A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings.
2 what is the difference between high frequency UPS and low frequency UPS?
Item | High frequency UPS | Low frequency UPS |
Input PF | 0.99 | 0.7 |
Efficiency | 85-90% | 75-85% |
Power density | Higher | Lower |
Power device capacity | Less | More |
Weight | Light | Heavy |
Dimension | Compact | Bigger |
Price | Lower | Higher |
Overload ability | Normal | Better |
Anti input sugar capacity | Normal | Better |
Output anti-crush , short circuit capacity | Normal | Better |
N-G voltage | Bad | Better |
Output component | More | Less |
Damage extent of device when it's fail | Higher | Lower |
Stability | Normal | Better |
Compatibility with generator | Bad | Better |
3 how to choose between standard model UPS and long time model UPS?
standard model UPS | long time model UPS |
standard model UPS power means within batteries inside UPS, the backup time would be only few minutes at full load | long time model UPS power means with external batteries, the backup time would be different according to the battery capacity |
If the backup time at full load is longer, long time model would be your choice , if the backup time at full load is shorter, standard model UPS would be enough |
4 how to contact me to get more details of HRD UPS power ?